HOW TO MAKE THE AIR-COOLED COMPRESSOR UNIT COOLING EFFECT STABLE?

Copeland Air-Cooled Hermetic Compressor Unit works effectively with a multi-step check that can be very helpful in saving power. It is presented with a breakdown caution and inquiry function empowering users to have a check on its performance. In extension to this, it has an edge over many other compressors as it has controllable fan activity with inhaling overheat of 10 ºC. Furthermore, it guarantees ample cooling potential with storage temperature moving between -5~5 ºC.

The next Copeland Air-Cooled Hermetic Compressor Unit supplier will introduce you to 5 steps to keep the cooling effect of the air-cooled compressor condensing unit stable all year round.

1. Regularly check the compressor of the air-cooled condensing unit

The compressor is the “heart” of the air-cooled condensing unit. Its quality directly affects the stability of the air-cooled condensing unit. If the compressor fails to repair, the cost is relatively high, especially the price of the compressor. Therefore, if you hear an abnormal sound or other conditions of the compressor, you must contact the air-cooled compressor condensing unit factory to find a professional engineer to check, find out the cause and carry out maintenance treatment.

2. Regularly clean the condenser and evaporator of air-cooled compressor condensing units

The condenser/evaporator is the second most important component of the air-cooled compressor condensing unit and should be cleaned once every six months. The cooling water of the water-cooled condenser is an open circuit, and the tap water used is recycled by the cooling water tower, which is easy to decompose and deposit impurities to form scale on the water pipe, affecting the heat transfer effect. Too much scale will also reduce the flow section of cooling water, reduce the amount of water, and increase the condensing pressure. Therefore, when the use of tap water quality is poor, should be cleaned at least once a year to remove the scale in the pipe, the tap water for water treatment operations.

3. Regular testing of cold water for the unit through the safety valve

The condenser and evaporator of the air-cooled compression condensing unit belong to their own pressure as well as the container, and according to the relevant regulations, a safety valve should be installed on the high pressure end of the air-cooled compression condensing unit, that is, the condenser body, so that once the unit is in an abnormal working life environment, the safety valve can realize automatic pressure relief to prevent the harm that may be caused to our human health due to high pressure.

4. Regularly replace the lubricating oil of air-cooled compressed condensing units

After long-term use of air-cooled compressed condensing units, the oil quality of lubricating oil will deteriorate, and the impurities and water in the oil will increase, so the oil quality should be regularly observed and checked. Once the problem is found, it should be replaced in time, and the brand of the replacement lubricant should be provided by the original manufacturer.

5.Regularly replace the filter drier of the air-cooled compressor condensing unit

A filter drier is an important component to ensure that the refrigerant carries out the normal development cycle of the enterprise. Since water and refrigerant are insoluble, if a system contains water, it will greatly affect the operation and management efficiency of the air-cooled compression condensing unit, so it is very important for us to keep the internal control of the information system company dry, and the filter element inside the filter drier must be replaced regularly.